Schneider Magnetic Contactor LC1D09BD
Brand Name: Schneider
Product Name: Contactor
Type: LC1D09BD
Electricity Type: DC
Lead Time: in stock
Shipping Method: DHL/ TNT/ FEDEX/ AIR/ OCEAN
Payment Method: Wire Transfer/ West Union/ PayPal/ Alipay
Schneider DC Magnetic contactor lC1D09BD 9A 24VDC 3P

Introduction
Are you in need of a reliable and high-quality contactor for your electrical needs? LC1D09BD contactor is perfect for various applications, from small residential projects to large industrial uses.
Our LC1D09BD contactor is an excellent choice for merchants expanding their product offerings. Reliable, versatile, and safe, it suits various applications from residential to industrial projects. Its user-friendly design and cost-effectiveness save time and money. When it comes to a high-quality and trustworthy contactor, LC1D09BD contactor is the ultimate solution.

Features
- Reliability: Built with high-quality materials such as copper and stainless steel, LC1D09BD can withstand daily wear and tear. Operating at temperatures up to 70°C and boasting a lifespan of over three million mechanical operations, this contactor is durable. Additionally, it offers high protection against dust and moisture, making it suitable for harsh and unpredictable environments.
- Versatility: LC1D09BD contactor is highly versatile, catering to a wide range of applications. With the capability to handle large currents (up to 9A) and a maximum rated operational voltage of 690V, it is suitable for residential, commercial, and heavy-duty industrial use. Its modular design allows for easy integration into various systems and configurations. Furthermore, the contactor is compatible with accessories like auxiliary contacts and control modules, enhancing its versatility.
- Safety: Safety is a top priority, and our LC1D09BD contactor is designed with safety in mind. It adheres to international safety standards such as IEC and UL, undergoing rigorous testing for electrical and mechanical safety. Safety features like reinforced insulation and protective covers minimize the risk of electric shock. The contactor also incorporates built-in overload and short-circuit protection, preventing system damage and potential hazards.
- Ease of Use: Clear and simple installation instructions make integration into various systems and configurations effortless. Its compact design allows for easy installation in tight spaces. Additionally, the contactor's modular construction simplifies maintenance and repairs.
- Cost-effectiveness: LC1D09BD contactor delivers high reliability, versatility, and safety. Its long lifespan requires minimal maintenance and replacement. Moreover, its low power consumption reduces energy costs, making it an ideal choice for businesses seeking energy bill savings.
Products Description
specification of schneider DC magnetic contactor LC1D09BD:
|
Range of product
|
TeSys D
TeSys Deca
|
|
Product or component type
|
Contactor
|
|
Device short name
|
LC1D
|
|
Contactor application
|
Motor control
Resistive load
|
|
Utilisation category
|
AC-4
AC-3
AC-1
AC-3e
|
|
Poles description
|
3P
|
|
Motor power kW
|
2.2 kW at 220...230 V AC 50/60 Hz (AC-3) 4 kW at 380...400 V AC 50/60 Hz (AC-3) 4 kW at 415...440 V AC 50/60 Hz (AC-3) 5.5 kW at 500 V AC 50/60 Hz (AC-3) 5.5 kW at 660...690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 2.2 kW at 220...230 V AC 50/60 Hz (AC-3e) 4 kW at 380...400 V AC 50/60 Hz (AC-3e) 4 kW at 415...440 V AC 50/60 Hz (AC-3e) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 5.5 kW at 660...690 V AC 50/60 Hz (AC-3e) |
|
Motor power hp
|
1 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors |
|
Pole contact composition
|
3 NO
|
|
Contact compatibility
|
M4
|
|
Protective cover
|
With
|
|
Auxiliary contacts type
|
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
|
|
Auxiliary contact composition
|
1 NO + 1 NC
|
|
[Ui] rated insulation voltage
|
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
|
|
[Uimp] rated impulse withstand voltage
|
6 kV conforming to IEC 60947
|
|
Overvoltage category
|
III
|
|
[Ith] conventional free air thermal current
|
25 A (at 60 °C) for power circuit
10 A (at 60 °C) for signalling circuit
|
|
Irms rated making capacity
|
250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
|
|
Rated breaking capacity
|
250 A at 440 V for power circuit conforming to IEC 60947
|
|
Control circuit type
|
DC standard
|
|
Coil technology
|
Built-in bidirectional peak limiting diode suppressor
|
|
Control circuit voltage limits
|
0.1...0.25 Uc (-40…70 °C):drop-out DC 0.7...1.25 Uc (-40…60 °C):operational DC 1...1.25 Uc (60…70 °C):operational DC |
|
Average impedance
|
2.5 mOhm - Ith 25 A 50 Hz for power circuit
|
|
Power dissipation per pole
|
1.56 W AC-1 0.2 W AC-3 0.2 W AC-3e |
|
Minimum switching current
|
5 mA for signalling circuit
|
|
Minimum switching voltage
|
17 V for signalling circuit
|
|
Non-overlap time
|
1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
|
|
Maximum operating rate
|
3600 cyc/h 60 °C
|
|
Inrush power in W
|
5.4 W (at 20 °C)
|
|
Hold-in power consumption in W
|
5.4 W at 20 °C
|
|
Insulation resistance
|
> 10 MOhm for signalling circuit
|
|
Tightening torque
|
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
|
Mounting support
|
Plate
Rail
|
|
Mechanical durability
|
30 Mcycles
|
|
Safety reliability level
|
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
|
Operating Aaltitude
|
0...3000 m
|
|
Compatibility code
|
LC1D
|
|
Product certifications
|
LROS (Lloyds register of shipping) CSA UL GOST DNV CCC GL BV RINA UKCA |
Condition of environment could schneider DC magnetic contactor LC1D09BD be used:
|
Climatic withstand
|
conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
|
Permissible ambient air temperature around the device |
-40…60 °C 60…70 °C with derating |
|
Fire resistance
|
850 °C conforming to IEC 60695-2-1
|
|
Mechanical robustness
|
Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor open (10 Gn for 11 ms) Shocks contactor closed (15 Gn for 11 ms) |
Dimension of schneider DC Magnetic contactor LC1D09BD:
|
Height
|
77 mm
|
|
Width
|
45 mm
|
|
Depth
|
95 mm
|
|
Net weight
|
0.48 kg
|
Certifications
Certificate of Authorized Distributor of Schneider Electrics

UL certificate for Schneider Electrics

TAF certification for Schneider Electrics

Shipping Methods

DHL Exrepss
3~7 days delivery

FEDEX Express
3~7 days delivery

AIR Transport
Heavy cargo ship via air with high efficiency.

OCEAN Transport
Heavy cargo ship via sea with competitiive shipping cost.
Payment Methods
1
Wire Transfer (T/T)
2
PayPal / Alipay
3
West Union
Hot Tags: schneider magnetic contactor lc1d09bd, schneider magnetic contactor lc1d09bd suppliers, contactor 125 amp, three phase contactor, aircon contactor, 100a contactor 3 pole, motor circuit breaker schneider, km contactor