Schneider Contactor LC1D09M7
Product Name: Contactor
Type: LC1D09M7
Electricity Type: AC
Lead Time: in stock
Shipping Method: DHL/ TNT/ FEDEX/ AIR/ OCEAN
Payment Method: Wire Transfer/ West Union/ PayPal/ Alipay
Schneider Ac Magnetic Contactor LC1D09M7 25A 220VAC 3P

Inntroduction
LC1D09M7-A High-Quality Contactor for Industrial Applications
The LC1D09M7 is a top-quality contactor that delivers superior performance, versatility, and safety for your industrial machinery needs. Its high-quality materials, versatile design, high-speed operation, compatibility, and safety features make it the best option available.
We guarantee excellent customer service and your satisfaction with your purchase. Choose the LC1D09M7 for durable, reliable, and cost-effective machinery components.

Features
- Cost-Effective: The LC1D09M7 is competitively priced, making it a cost-effective option for your machinery needs. Its high-quality material and design make it a reliable and durable component that will provide long-lasting service, saving you money in the long run.
- Easy to Use: The LC1D09M7 is easy to install, maintain, and replace. Its versatile design allows for quick and easy integration into your existing machinery. Its high-speed operation ensures that it will perform reliably and efficiently, giving you peace of mind.
- High-Quality: The LC1D09M7 is manufactured using high-quality materials and designed with safety in mind, ensuring its durability and reliability. Its ability to perform well in a wide range of industrial applications makes it an ideal choice for your machinery needs.
- Excellent Customer Service: Our company is committed to providing excellent customer service to ensure your satisfaction. We strive to offer high-quality products at competitive prices and make sure our customers are fully satisfied with their purchase.
Products Description
Specification of Schneider AC magnetic contactor lC1D09M7:
|
Main
|
|
|
Range
|
TeSys
TeSys Deca
|
|
Range of product
|
TeSys D
TeSys Deca
|
|
Product or component type
|
Contactor
|
|
Device short name
|
LC1D
|
|
Contactor application
|
Motor control
Resistive load
|
|
Utilisation category
|
AC-4
AC-3
AC-1
AC-3e
|
|
Poles description
|
3P
|
|
Motor power kW
|
2.2 kW at 220...230 V AC 50/60 Hz (AC-3)
4 kW at 380...400 V AC 50/60 Hz (AC-3)
4 kW at 415...440 V AC 50/60 Hz (AC-3)
5.5 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3)
2.2 kW at 400 V AC 50/60 Hz (AC-4)
2.2 kW at 220...230 V AC 50/60 Hz (AC-3e)
4 kW at 380...400 V AC 50/60 Hz (AC-3e)
4 kW at 415...440 V AC 50/60 Hz (AC-3e)
5.5 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
|
|
Motor power hp
|
1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
|
|
Pole contact composition
|
3 NO
|
|
Contact compatibility
|
M2
|
|
Protective cover
|
With
|
|
Auxiliary contacts type
|
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
|
|
Auxiliary contact composition
|
1 NO + 1 NC
|
|
[Ui] rated insulation voltage
|
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
|
|
[Uimp] rated impulse withstand voltage
|
6 kV conforming to IEC 60947
|
|
Overvoltage category
|
III
|
|
[Ith] conventional free air thermal current
|
25 A (at 60 °C) for power circuit
10 A (at 60 °C) for signalling circuit
|
|
Irms rated making capacity
|
250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
|
|
Rated breaking capacity
|
250 A at 440 V for power circuit conforming to IEC 60947
|
|
Control circuit type
|
AC at 50/60 Hz
|
|
Coil technology
|
Without built-in suppressor module
|
|
Control circuit voltage limits
|
0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
|
|
Average impedance
|
2.5 mOhm - Ith 25 A 50 Hz for power circuit
|
|
Power dissipation per pole
|
1.56 W AC-1
0.2 W AC-3
0.2 W AC-3e
|
|
Minimum switching current
|
5 mA for signalling circuit
|
|
Minimum switching voltage
|
17 V for signalling circuit
|
|
Non-overlap time
|
1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
|
|
Maximum operating rate
|
3600 cyc/h 60 °C
|
|
Inrush power in VA
|
70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
|
|
Hold-in power consumption in VA
|
7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
|
|
Insulation resistance
|
> 10 MOhm for signalling c
|
|
Tightening torque
|
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m - on screw clamp terminals- with screwdriver Philips No 2
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit: 1.7 N.m - on screw clamp terminals -with screwdriver pozidriv No 2
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
|
|
Mounting support
|
Plate
Rail
|
|
Mechanical durability
|
15 Mcycles
|
|
Safety reliability level
|
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
|
|
Operating altitude
|
0...3000 m
|
|
Compatibility code
|
LC1D
|
|
Product certifications
|
BV
LROS (Lloyds register of shipping)
UL
GOST
GL
DNV
CSA
RINA
CCC
UKCA
|
condition of environment could schneider ac magnetic contactor lC1D09M7 be used:
|
Environment
|
|
|
Climatic withstand
|
conforming to IACS E10
conforming to IEC 60947-1 Annex Q category D
|
|
Ambient air temperature for storage
|
-60…80 °C
|
|
Fire resistance
|
850 °C conforming to IEC 60695-2-1
|
|
Mechanical robustness
|
Vibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 4 Gn, 5...300 Hz
Shocks contactor open: 10 Gn for 11 ms
Shocks contactor closed: 15 Gn for 11 ms |
Dimension of Schneider ac magnetic contactor LC1D09M7 be used:
|
Dimension
|
|
|
Height
|
77 mm
|
|
Width
|
45 mm
|
|
Depth
|
86 mm
|
|
Net weight
|
0.32 kg
|
Related Products

LC1D18M7

LC1D25M7

LC1D32M7

LC1D40AM7

LC1D50A7

LC1D65AM7

LC1D80M7

LC1D95M7
Certification
Certificate of Authorized Distributor of Schneider Electrics

UL certificate for Schneider Electrics

TAF certification for Schneider Electrics

Shipping Method

DHL Exrepss
3~7 days delivery

FEDEX Express
3~7 days delivery

AIR Transport
Heavy cargo ship via air with high efficiency.

OCEAN Transport
Heavy cargo ship via sea with competitiive shipping cost.
Payment Method
1
Wire Transfer (T/T)
2
PayPal / Alipay
3
West Union
Hot Tags: schneider contactor lc1d09m7, schneider contactor lc1d09m7 suppliers, a1 and a2 on a contactor, air contactor, contactor ls mc 9b, cjx2 2510 contactor, changeover contactor, contactor modular 25a
Send Inquiry